Flood Risk Assessment, SuDS and Sequential Test, Oadby
A two-court covered padel centre on a vacant, wholly hard-surfaced former industrial yard of 1,574 m² at 43a Kenilworth Drive, Oadby. The site is in Flood Zone 1 but carries mapped surface water risk, so the flood risk Sequential Test is engaged under NPPF policy F5(2) unless an exemption applies. The Air & Flood Consultants report found the surface-water-only exemption at F5(2)(b)(ii) engaged, ran a full test of ten alternative sites across the Borough of Oadby and Wigston without prejudice, and set out a drainage strategy for an unchanged impermeable area. Oadby and Wigston Borough Council granted application 26/00170/FUL on 23 October 2026.

The site is a vacant former industrial yard of 1,574 m² at 43a Kenilworth Drive, Oadby, from which both previous buildings have been demolished. It is wholly hard surfaced. The proposal is a padel centre of two covered courts with ancillary office and changing units, fencing and thirteen parking spaces. The site lies in Flood Zone 1 on the Environment Agency Flood Map for Planning, and the use is Water-Compatible under Annex F, table 2 of the National Planning Policy Framework. Air & Flood Consultants prepared a combined Flood Risk Assessment, Sustainable Drainage Strategy and Flood Risk Sequential Test in September 2026 for planning application 26/00170/FUL.
Surface water governs. The Environment Agency's High band (1 in 30 or more frequent) covers 4.5 m² of the site, 0.3%, against the southern boundary and outside the development. The Medium band covers 572.7 m² (36.4%), mainly in the western part, where Court 2 sits. In total 62.0% of the site lies within the 1 in 1000 extent at present day and 68.7% with the climate change allowance, with modelled depths predominantly below 150 mm and in the 150 to 300 mm band over approximately 81 m². Court 1 and the access lie within a contiguous 460 m² outside the extent of every modelled event, which is designated as the place of safe refuge. Sewer flood risk was assessed as medium, and tidal, fluvial, groundwater and artificial-source risks as low.
Policy F5(2) of the NPPF applies the Sequential Test in areas at risk from any form of flooding, so a Flood Zone 1 location does not of itself put a site outside it. The report found the exemption at F5(2)(b)(ii) engaged for a site at risk of surface water flooding only: the medium sewer rating rests on rainfall-driven surcharge, and the Level 1 Strategic Flood Risk Assessment records the event of 22 June 2023 as surface water and sewer flooding together. A full test was carried out nonetheless across the Borough of Oadby and Wigston. Ten alternative sites were drawn from marketed listings captured on 13 September 2026, the Brownfield Land Register, the Employment Land Availability Study and the Call for Sites. On the 1 in 30 extent the application site carries 0.3% of its area, against 2.5%, 12.2%, 62.1% and none at the four candidates sampled. None of the ten was found both reasonably available and appropriate, and no Exception Test is required for Water-Compatible use in Flood Zone 1.
The courts and units add 459 m² of roof over existing hardstanding, so the impermeable area is unchanged at 1,574 m². Infiltration was ruled out: the ground is Blue Lias Formation mudstone with an indicative permeability below 1×10⁻⁶ m/s on the proprietary Air & Flood Consultants infiltration potential model, and a historic landfill boundary lies 11 m from the site. The Wash Brook is 214 m away across third-party land. The strategy provides a 300 litre rainwater planter at each court, a 100 litre harvesting store for WC flushing, catchpits and trapped gullies, and discharge of the balance to the existing connection. Sealed thresholds, sockets at least 300 mm above external ground and backflow protection are specified for the office and changing units.
Oadby and Wigston Borough Council granted planning permission under delegated powers on 23 October 2026 under reference 26/00170/FUL.
More on these services:
Flood risk assessments: https://www.airandfloodconsultants.co.uk/floodrisk
SuDS strategies: https://www.airandfloodconsultants.co.uk/suds
The Sequential Test under the NPPF 2026: https://www.airandfloodconsultants.co.uk/post/sequential-test-nppf-2026